The City of Austin grease trap requirements sit in Chapter 15-10 of the Austin City Code. Commercial and institutional food businesses need an approved grease trap, apart from exceptions the code names. A hauler with a City permit empties it completely at least every ninety days, or sooner once grease and solids fill half of its wetted height, and the manifest records are kept for at least three years.
Most of that is handled between you and your pumping company. One duty is about the trap itself: the code says it must be maintained, and no pump-out closes a crack or puts a broken baffle wall back.
City documents last reviewed: code sections November 9 and 12, 2026; Austin Water pages November 12, 2026
Austin grease trap requirements in one table
The first two columns come from the code. The last column is our plain reading of who normally takes care of each duty.
| What the code requires | Section | Who normally takes care of it |
|---|---|---|
| An approved pretreatment facility (for a kitchen, the grease trap) at commercial or institutional food preparation businesses, except where the code points to an exception | § 15-10-71 | The business or property owner |
| A full cleaning at least every ninety days, or when grease and solids reach 50 percent of the wetted height, whichever is earlier | § 15-10-197(A)(2) | You book it; a permitted hauler pumps it |
| Everything taken out at each cleaning, residue included | § 15-10-197(A)(1) | The hauler. Austin Water advises you to be present |
| Waste removed only by a hauler the director has permitted | § 15-10-197(A)(3) | The hauler |
| Each removal documented on a manifest the director has approved | § 15-10-197(A)(4) | The hauler provides it; you keep it |
| Records kept for at least three years | § 15-10-165(B) | You |
| No fat, oil or grease discharged above the City’s limit | § 15-10-23 | You, through kitchen habits and a trap that works |
| The trap operated and maintained | § 15-10-71 | You. Damage to the trap is a repair job |
Who writes the City of Austin grease trap requirements?
The City, in Chapter 15-10 of the City Code, its wastewater chapter. Austin Water’s Grease Trap Maintenance page sums it up: “Maintenance and documentation requirements for grease traps under Austin City Code are outlined in Chapter 15-10.”
The state’s guidance agrees on who approves the trap. TCEQ (the Texas Commission on Environmental Quality) says in its guide RG-389 that the authorization and installation of grease traps are regulated by local ordinances, the local wastewater utility, or both. TCEQ itself regulates the pumping, transport and disposal of the waste. Questions on that side go to TCEQ.
Austin Water’s FAQ sends building plan review, and the approval letters for new traps, through its Industrial Waste staff.
Which kitchens do Austin grease trap requirements apply to?
§ 15-10-71 applies to a person operating a commercial or institutional food preparation business, and its list is long: “a food processor, bakery, restaurant, school, hospital, retirement home, assisted living center, grocery store or other commercial or institutional food preparation operation”. The current text says each of them “must construct, operate, and maintain a pretreatment facility approved by the director, except as provided in Section 25-12-32 (Grease Traps).” Section 25-12-32 says a grease trap is not required for a food establishment that “serves only beverages” or “is a Category 1 or Category 2 charitable feeding organization”. If you aren’t sure whether that fits your site, ask Austin Water’s Industrial Waste staff.
Austin Water’s FAQ explains the term: grease traps “are pretreatment devices that separate fats, oils and grease (FOG) along with food preparation solids from wastewater before it enters the City’s sanitary sewer system.” The City’s pages use both names, grease trap and grease interceptor; the FAQ notes that the two “use different designs”.
The size isn’t yours to pick. Austin Water sets it in an approval letter during building plan review, and its sizing page warns: “Do not purchase a grease trap or interceptor before obtaining building plan approval and an Industrial Waste approval letter specifying the required size and design.” It also says: “Grease traps and interceptors with a minimum liquid holding capacity below 100 gallons will not be approved for installation.” And for kitchens with a dishwasher: “Commercial food preparation facilities that use a dishwasher must install a minimum 500-gallon (liquid holding capacity) grease interceptor.”
Does every food business in Austin need a grease trap?
Some sites can ask to go without one. Austin Water’s FAQ names businesses “serving only pre-packaged foods in the original unopened container, providing drinks only or cutting fruits”, which can apply with a Grease Interceptor Installation Variance Request Form. Its Relief Program page adds: “Beginning Oct. 1, 2026, a new FOG risk-based system will be used to determine whether establishments may qualify for a variance.” The same page sets a condition: “Any exemption is contingent on following FOG Best Management Practices.”
Whether your site qualifies is Austin Water’s decision, not ours. Ask its Industrial Waste staff at IndustrialWaste@austintexas.gov.
What do the Austin grease trap cleaning requirements say?
Under § 15-10-197(A)(2), anyone who discharges wastewater from a grease trap has to clean it at the earlier of two points:
“(a) at least every ninety days; or
(b) when 50 percent or more of the wetted height of the grease trap, as measured from the bottom of the grease trap to the invert of the outlet pipe, contains grease and solids”
Read in plain words:
- Whichever comes first. If grease and solids reach the 50 percent line before ninety days have passed, the trap is due then. Austin Water’s FAQ adds: “The right frequency varies by business.”
- Wetted height. The code measures it from the bottom of the trap up to the invert of the outlet pipe. “Invert” is the code’s measuring point at that pipe; your hauler can show you where it sits on your trap.
- For example. In a trap whose wetted height is 4 feet, grease and solids reaching 2 feet put it at 50 percent.
- A complete job. The same section says to “completely remove all fat, oil, or grease waste, other liquid waste, semi-solid or solid and residue from the grease trap when the grease trap is cleaned”. Skimming the top doesn’t meet it.
Two more sentences in § 15-10-197 concern the director. The first: “The director may establish other cleaning requirements for grease traps as necessary to protect the POTW or a portion of the sanitary sewer.” POTW stands for publicly owned treatment works. The second: “The director may reduce the cleaning frequency requirement in writing if the director determines, based on written documentation submitted by the generator, that the reduced cleaning frequency does not contribute to or cause a violation of this chapter.” Austin Water’s forms list includes a Reduced Grease Trap Cleaning Frequency Application. Our repair warranty still asks for regular pump-outs.
To find your own schedule, Austin Water suggests: “Ask your maintenance provider to take periodic grease and sludge layer measurements to determine the appropriate schedule.”
Can enzymes or bacteria stretch the time between pump-outs?
Austin Water says no to adding them to the trap. Its sizing page states: “Under Austin City Code § 15-10-22(23), the use of enzymes, chemicals or other agents to cause oil, grease and solids to pass through a pretreatment facility is prohibited.” Its maintenance page explains why: “While these substances will temporarily help liquify FOG, it will re-congeal further down in the pipes.”
Who do Austin grease trap requirements allow to empty a trap?
A permitted hauler. § 15-10-197(A)(3) says to “use a liquid waste hauler permitted by the director to remove the grease trap waste”, and (A)(4) says to “document the removal of the hauled liquid waste from the grease trap using a manifest approved by the director.” Austin Water’s maintenance page describes the records as “Manifest records provided by the liquid waste hauler after each pump-out”.
Austin Water’s FAQ describes the same hauler as “a liquid waste hauler licensed by the Texas Commission on Environmental Quality and permitted by the City of Austin”. As of September 2026, its forms list included a “List of Liquid Waste Haulers with a Valid City of Austin Permit”. If you’re not sure your company is on it, check that list or ask Austin Water.
The same FAQ ties inspection to servicing: “An Industrial Waste staff member must be present while the grease trap is being serviced to perform the inspection.” If an inspection has already gone against you, our page on what to do after a failed grease trap inspection in Austin takes it step by step.
Can my kitchen staff pump out the trap themselves?
Under § 15-10-197(A)(3), the waste goes out with “a liquid waste hauler permitted by the director”. Your part is to be there. Austin Water’s tip: “Be present for GT pump-outs and talk to your liquid waste hauler (LWH) about the percentage of grease and solids in the interceptor as well as the condition of the pretreatment device itself.” GT is the City’s short form for grease trap.
We don’t pump traps or haul waste, so we never provide manifests. For a missing one, ask your hauler.
Which records do Austin grease trap requirements ask you to keep?
The manifests. § 15-10-165(B) is the rule: “a person shall retain records under this chapter for at least three years from the date the record is created”. Austin Water’s maintenance page says where: manifest records from the hauler “must be kept on site for three years”.
TCEQ’s RG-389 adds a reason to keep them in order: the business that produces grease trap waste stays responsible for its waste until it reaches the proper disposal facility.
How do Austin grease trap requirements treat the trap’s condition?
The duty in § 15-10-71 is to “construct, operate, and maintain” the trap, not only to keep it pumped. Austin Water’s maintenance page puts the trap’s side this way:
- “If a pump-out manifest provided to you by the LWH indicates that the GT needs repair, take appropriate action to have it serviced immediately.”
- Keep the trap reachable: the page asks you to check regularly that lids aren’t blocked, bolts aren’t seized and covers aren’t damaged.
Its spill-prevention list, about plumbing and drain lines in general, adds: “Promptly address slow drains, backups, overflows, leaks, or other plumbing issues.”
There is also a limit on what leaves the trap. Under § 15-10-23, “a person may not discharge fat, oil, grease, or similar material to the POTW in excess of an instantaneous limit of 200 milligrams per liter.” On kitchen habits, one line is a rule rather than a tip: “Never use food grinders or disposals as these have been prohibited in commercial kitchens in the Austin Water service area since 2008.”
What else do Austin grease trap requirements cover?
A few duties sit beside the trap itself. In Austin Water’s words:
- Sample port. “A sample port is required for any facility discharging wastewater regulated under Chapter 15-10 of the Austin City Code.”
- Discharge permit. “A permit is required for any discharge of industrial wastewater into the City’s wastewater collection system.”
- Surcharge. “Wastewater surcharge fees are charged to businesses whose wastewater discharge exceeds normal wastewater standards, to help cover the cost of treatment as required by federal regulations.”
- A trap taken out of service. Austin Water publishes Grease Trap Abandonment Requirements for properties on its wastewater service, and a separate procedure for traps connected to septic tanks.
Each has its own page on austintexas.gov; the FAQ under Sources links them.
What happens when City of Austin grease trap requirements aren’t met?
Austin Water’s maintenance page warns: “Failure to meet any one of these maintenance or documentation requirements is a separate violation of the Austin City Code.” The same page adds: “Potential penalties include fines and permit revocations.”
The enforcement sections of Chapter 15-10 give the City these tools:
- Civil suit, § 15-10-252. “If a person has received actual notice of the provisions of this chapter”, the City may sue “to recover a civil penalty not to exceed $5,000 a day for each violation”.
- Criminal offense, § 15-10-251. A separate route: “An offense under this chapter is a class C misdemeanor”. For that offense, “Proof of a culpable mental state is not required for a conviction of an offense under this chapter.”
- Water or wastewater service, §§ 15-10-253 and 15-10-256. The director may suspend service in an emergency, or “issue an order terminating water or wastewater service to the person’s premises” after a violation.
- A published list, § 15-10-311. Once a year the director publishes the users found “in significant noncompliance with applicable pretreatment requirements during the previous 12 months”. It is not a list of every missed pump-out: for most users, § 15-10-311(A) limits significant noncompliance to a few kinds of violation, such as a discharge “that has caused imminent endangerment to the public or to the environment”.
What each of these means after a failed visit, and what to do in what order, is on our failed grease trap inspection page.
The Relief Program and City of Austin grease trap requirements
Austin Water runs a Grease Trap Relief Program. As the program page read on October 11, 2026: “Beginning Oct. 1, 2026, qualifying and approved establishments within the City of Austin may receive no-cost grease trap equipment and installation or replacement.”
The same page speaks to who needs a trap: “Some businesses previously required to install a grease trap may no longer need one, and some with existing traps may not need to replace them.” It ties that to the new risk-based system for variances quoted in the section on which kitchens need a trap. On monitoring, it says that “in some cases, data may support a pump-out frequency variance (less frequent than every 90 days per § 15-10-197 )”.
Points from that page worth knowing before you apply:
- “Submission does not guarantee approval.” A selection committee scores applications, and the City’s resolution “designates small, locally owned businesses and CFOs as the primary beneficiaries of the program”. CFO stands for charitable feeding organization.
- “Applicants must complete the online application” on Austin Water’s site. Then “Austin Water will coordinate the work with a City-approved contractor and pay the contractor directly upon a successful post-installation inspection.”
- After installation the trap is yours: “all future maintenance and repair costs are the responsibility of the food establishment or property owner”.
Whether the program fits your site, and what it changes for you, is for Austin Water to say. Questions go to AWGreaseTrapRelief@austintexas.gov.
What do Austin grease trap requirements mean for a full or damaged trap?
Start by asking what the problem is.
| What you’re seeing | Who to call |
|---|---|
| The trap is due by date or by the 50 percent line, or it’s simply full | Your permitted hauler. A full trap needs a pump-out, not a repair |
| A manifest is missing | Your hauler, who provides it |
| The hauler or an inspector reports cracks, holes, corroded walls or a broken baffle wall | A repair. That is our work |
| The hauler finds a blockage in the line into or out of the trap | Sewer line jetting |
| There is no trap, or the one you have can’t be saved | A new trap. Read the Relief Program section first, and ask Austin Water’s Industrial Waste staff what approval the new trap needs |
Grease trap repair. After your hauler has pumped the trap out, our crew closes the holes and cracks, rebuilds broken walls and coats the entire trap. We work overnight and the trap is ready the next morning. We repair cast concrete, steel and fiberglass traps of all sizes, underground or above ground. Read how grease trap repair works in Austin.
Each repair is guaranteed to pass inspection: we repair with high industrial-grade materials, back to the trap’s original specifications. The guarantee is about the trap itself; pump-out timing, manifests and the grease limit stay with you and your hauler. Each repair also carries a 10-year warranty on labor and materials, as long as the trap gets regular pump-outs.
Sewer line jetting. It clears blockages in the line, up to 200 feet from each side of the trap. See sewer line jetting in Austin.
Grease trap installation. We install new grease traps to the size and design Austin Water approves. See grease trap installation in Austin.
The first step is a free inspection: a technician of ours looks at the trap on site and tells you whether it can be repaired. It is our own check, not a City inspection.
Does a repaired trap keep the same pump-out schedule?
§ 15-10-197 makes no exception for a repaired trap: at least every ninety days, or at 50 percent of the wetted height, whichever comes first. Our warranty also holds only as long as the trap gets regular pump-outs. Any change to how often your trap must be cleaned is Austin Water’s decision.
Sources
- Austin City Code, Chapter 15-10, Wastewater Regulations (Municode, version of August 26, 2026, read November 9, 2026)
- Austin City Code, § 15-10-197, Requirements for cleaning grease traps (Municode, read November 9, 2026)
- Austin Water, Grease Trap Maintenance (read October 11, 2026)
- Austin Water, Grease Trap Relief Program (read October 11, 2026)
- Austin Water, Pretreatment Requirements and Resources (read September 14, 2026)
- Austin Water, Grease Trap Sizing and Design Criteria (read September 14, 2026)
- Texas Commission on Environmental Quality, RG-389, Waste from Grease Traps, Grit Traps, and Septic Tanks (PDF) (Revised August 2026, read September 10, 2026)
This page explains the City’s rules in plain words. It isn’t legal advice; the code text governs.
City documents last reviewed: code sections November 9 and 12, 2026; Austin Water pages November 12, 2026
Page last updated: November 2026